The cart is empty.
Dealers. First. Always.
DWG

SLE-FNI-CFB Napco Commercial FirstNet Dual Path Fire Alarm Communicator Metal Enclosure - Red

SKU: SLE-FNI-CFB

Agency Compliance

  • UL985 Household Fire Warning System
  • UL864 10th Edition Control Units For Fire Alarm Systems Powered by Control Panel
  • Input: 12-24VDC (100mA @ 24VDC w/peak RF transmission draw of 200mA)

Also includes

  • (4) Programmable EOLR Zone inputs for connection to legacy FACPs
  • (2) Form C relay outputs, eliminating the need for additional listed supervision relay
  • (2) Modular RJ45 Telco jacks for easy connection to FACP
More details...
MSRP Price: $410.58
Web Price: $410.58
Save to my Wish List
Product Details

The StarLink LTE Series Dual-Path Commercial / Residential Fire alarm capture radio IP communicators are fully supervised, wireless digital two-way subscriber units. All models are compatible with most 12/24VDC alarm control panels (always adhere to the documentation provided by the control panel manufacturer). These communicators are for use as the primary means of communication with the central station and do not have backup mode capability. No POTS (Telco Line) connection permitted.


Specifications


Electrical Ratings for 120VAC, 60Hz For Models with Power Supply

  • Input Voltage - 120VAC nominal
  • Input Current - 200mA maximum
  • Maximum Charging Current - 200mA

Electrical Ratings for +12V / 24V For Models without Power Supply†

  • Input Voltage - 10-25VDC regulated (power-limited out-put from Listed control panel Aux/Remote Fire Power)
  • Input Current
    • 10VDC standby: 162mA
    • 12VDC standby: 125mA
    • 15VDC standby: 110mA
    • 24VDC standby: 100mA
    • 25VDC standby: 100mA
  • Wi-Fi Module - (Optional) Add 40mA to the above. (With peak RF transmission current of 325mA)

Electrical Ratings for the IN 1 Fire Input

  • Input Voltage - 9-25VDC
  • Maximum Input Current - Up to 2mA from FACP NAC circuit

Electrical Ratings for IN 2, IN 3, IN 4, and IN 5: (Inputs IN 2, IN 3, IN 4, and IN 5 are Class B)

  • Maximum Loop Voltage - 25VDC
  • Maximum Loop Current - 1.2mA
  • End of Line Resistor (EOLR) Value - 10K (2 req'd)

Electrical Ratings for PGM3 Output

  • Open Collector Output - Maximum Voltage 3V when active; 25V maximum when not active
  • Maximum PGM Sink Current - 50mA (up to 15VDC), 25mA (15.1VDC - 25VDC)

Physical (W x H x D)

  • Metal Housing - 11½ x 9½ x 3½" (29.2 x 24.1 x 8.9cm)
  • Mounting - Metal housing includes two keyhole slots for wall mounting

Environmental

  • Operating Temperature - 0°C - 49°C (32°F - 120°F)
  • Humidity - Maximum 93% Non-Condensing
  • Indoor / dry location use only